Controls: Both chambers are equipped with their own electronic control, thermocouples and solid state relays. Auto tuning microprocessor based controls are accurate to ± 1/4 of 1%. Each chamber is equipped with door safety switches that remove power from that chambers heating elements and fan blower.
Heating Elements: Alloy wire elements are coiled and mounted on the side walls in easy to change porcelain plates.
General Construction: Case is constructed of galvanized sheet metal and mounted in angle steel frame. Space is provided for air circulation between chambers, the optional quench tank is stored beneath the lower chamber and can be rolled out for use. The control panel face is attractive brushed stainless steel.
The upper chamber door rises vertically, the lower chamber door swings to the side. A heavy duty chrome plated latch is used to hold the lower door closed. The lower chamber is equipped with a stainless steel, centrifugal type fan to circulate the air and provide very close temperature gradients. The fan is operated by a 1/4 HP motor.
Easy access to controls and wiring is provided by removable side panel on control cabinet.
Welded steel plate quench tank on caster is standard on most dual units. Door seal is standard for inert protective atmosphere on 2250°F chambers.
Upper Chamber Width |
N/A 10.5 in |
Upper Chamber Length |
N/A 13 in |
Upper Chamber Height |
N/A 8 in |
Lower Chamber Width |
N/A 10.5 in |
Lower Chamber Length |
N/A 10 in |
Lower Chamber Height |
N/A 8 in |
Overall Width |
N/A 25 in |
Overall Length |
N/A 43 in |
Overall Height |
N/A 28 in |
Max. Temperature Upper Chamber |
N/A 2250 ºF |
Max. Temperature Lower Chamber |
N/A 1250 ºF |
Input Power |
N/A 6 kW |
Weight |
N/A 400 lb |
Options |
N/A 3 phase 480 volts Audible buzzer High limit controls Inlet port for protective inert Atmosphere |